Abstract
There is an extraordinary urgency to limit hydrocarbon pollution and CO2 emissions. Due to their high temperatures and flow rates, parabolic trough collectors (PTCs) are used in industry to harness solar energy. Various studies have been carried out to improve PTC efficiency and performance. Multiple methods have been suggested; however, improving the transfer of heat between the absorber tube and heat transfer fluid (HTF) has the most impact. The current investigation introduces a new geometric modification for the absorber tube by utilizing four different inner dimples with and without conical tubes to promote thermal–hydraulic performance. The parametric study is conducted numerically using Ansys Fluent in combination with TracePro under a wide range of Reynolds number (Re) between 20,000 and 100,000 to assess the thermal performance, i.e., Nusselt number (Nu), thermal efficiency (ηth), and exergetic efficiency (ηexe). In addition, the friction coefficient (f) has also been evaluated to demonstrate the hydraulic performance. Lastly, the combination of both the thermal and hydraulic performance is also reported through the thermal enhancement factor (TEF), adjusted thermal (ηth-adj.), and exergetic (ηexe-adj.) efficiencies. It was found that despite the promising enhancement of heat transfer associated with the dimples in conical tubes starting from 80% up to 150%, the friction coefficient leaped significantly, ranging between 400 and 900%, and even recorded six times that percentage in certain cases depending mainly on the dimple design and Re. The TEF showed that the dimpled tubes with a slight convergence of the outlet diameter (DR = 1.25) operated effectively at low Re. Besides, it also highlights that the best dimple design to use the stepped-conical dimple as the overall thermal–hydraulic performance increased over 20% at Re equal to 20,000. On the other hand, the smooth absorber tube with a DR = 1.25 showed the exact outcome at Re exceeding 80,000. Finally, a comparison with the previously proposed techniques has also been conducted. Clearly, the dimpled and smooth conical perform well in their categories. In conclusion, the study offers two promising designs to increase PTC thermal performance at low and high mass fluxes for a variety of industrial applications.
First Page
6259
Last Page
6286
Recommended Citation
APA Citation
Al-Tohamy, A.
Ismail, O.
&
Kaood, A.
(2025). Hydrothermal performance evaluation of parabolic trough collector with conical dimpled receiver. Journal of Thermal Analysis and Calorimetry, 150(8), 6259–6286.
https://doi.org/10.1007/s10973-025-14115-w
MLA Citation
Al-Tohamy, Amro H., et al.
"Hydrothermal performance evaluation of parabolic trough collector with conical dimpled receiver." Journal of Thermal Analysis and Calorimetry, vol. 150, no. 8, 2025, pp. 6259–6286.
https://doi.org/10.1007/s10973-025-14115-w